DFN · GFN (L / DP / GP basin options) · VFD or PM direct drive
DFN / GFN Square Counter-Flow FRP Cooling Tower
Modular square cells that stack into the capacity the plant actually needs.
DFN and GFN square counter-flow towers are improved designs built on the test data of the China Machinery Ministry No.4 Design & Research Institute. The fan can run on a variable-frequency motor or a low-noise permanent-magnet direct-drive motor, with temperature sensors trimming fan speed to the real load. Cells are modular: single-row or double-row arrangements, pipe directions rotatable in 90° steps, and three basin depths so the tower can sit on a slab, in a pit or over a plant-room roof.
Specification
| Tower type | Square counter-flow, induced draft, FRP shell, modular multi-cell |
|---|---|
| Cell arrangement | Single-row or double-row multi-cell; add cells instead of oversizing one |
| Fan drive | Variable-frequency motor or low-noise permanent-magnet direct drive |
| Control | Temperature-sensor driven, real-time fan adjustment |
| Pipe direction | Inlet and outlet rotatable by 90°, 180°, 270° |
| Water basin | L — no basin · DP — shallow basin · GP — deep basin, 400 mm effective depth |
| Design conditions | Standard 5 °C range (D / CD) · industrial 10–25 °C (G type) |
| Inlet water | Up to 60 °C (higher on request) |
| Water quality | Circulating turbidity ≤ 50 mg/L, short term ≤ 100 mg/L |
| Cold resistance | −50 °C; anti-icing required below −10 °C monthly average |
Design notes
- Cells, not one big towerA failed cell is isolated and the plant keeps running at reduced capacity; the same cell size covers a 20 % expansion without a new tower.
- Direct drive where noise mattersThe permanent-magnet direct-drive option removes the belt and gearbox, cutting the dominant low-frequency noise and the maintenance interval with it.
- Three basin depthsNo basin for pit installations, shallow basin for slab mounting, 400 mm deep basin where pump suction needs the volume.
- Rotatable connectionsInlet and outlet can be turned 90°, 180° or 270° on site, which saves a header rework when the plant room layout changes.
Options
- Dual-speed motor control cabinet (supplied separately)
- Flame-retardant fill and casing option
- Basin heater and anti-icing control
- Stainless basin and fasteners for coastal sites
Applications
- Commercial and light industrial cooling
- District and campus condenser water
- Plant-room roof and pit installations
- Phased projects where cells are added over time
Same series
Closed loop · custom
Cooling Towers — FRP, Steel & Concrete
Closed Circuit Cooling Tower
Process fluid …
Tower typeClosed …
Open data sheet →
Low profile · easy service
Cooling Towers — FRP, Steel & Concrete
DBHZ₂ / CDBHZ₂ Square Cross-Flow FRP Tower
Air across the…
Tower typeSquare …
Open data sheet →
3–8 °C drop · to −50 °C
Cooling Towers — FRP, Steel & Concrete
DBNL₃ Circular Counter-Flow FRP Cooling Tower
Round shell, b…
MotorIP55, class F insulation, sealed waterproof, heat resistant
Tower typeCircula…
Open data sheet →