SJG
SJG Diagonal Flow Fan
Short drum, small inlet: built for tight duct runs.
- Frame sizes16
- Airflow200–25,000 m³/h
- Pressure to1,200 Pa
- Duty points64
A drum or straight casing with conical hub and twisted blades, designed for installations where duct length is limited. Small inlet and outlet diameters accelerate airflow and raise pressure in a short body.
Specification
| Casing | Drum or straight, spun flanges, steel |
|---|---|
| Impeller | Conical hub, twisted aerofoil blades |
| Mounting | Horizontal or vertical |
| Speed | VFD or dual speed available |
| Options | EXdIIBT4 explosion-proof |
Performance table
Measured on the factory test stand: 16 frame sizes, 200–25,000 m³/h, up to 1,200 Pa — 64 points on file. Standard air 20 °C, 101.3 kPa.
SJG
16 sizes| Size | Speed (rpm) | Q (m³/h) | Pt (Pa) | Motor | kW | dB(A) | Weight (kg) |
|---|---|---|---|---|---|---|---|
| 2F | 1450 | 200 | 110 | Y561-4 | 0.06 | 58 | 16 |
| 400 | 91 | Y561-4 | 0.06 | 58 | 16 | ||
| 500 | 70 | Y561-4 | 0.06 | 58 | 16 | ||
| 600 | 54 | Y561-4 | 0.06 | 58 | 16 | ||
| 2.5F | 1450 | 300 | 180 | Y632-4 | 0.18 | 60 | 24 |
| 450 | 165 | Y632-4 | 0.18 | 60 | 24 | ||
| 600 | 150 | Y632-4 | 0.18 | 60 | 24 | ||
| 1000 | 110 | Y632-4 | 0.18 | 60 | 24 | ||
| 3F | 1450 | 500 | 260 | Y712-6 | 0.37 | 61 | 27 |
| 750 | 240 | Y712-6 | 0.37 | 61 | 27 | ||
| 1500 | 170 | Y712-6 | 0.37 | 61 | 27 | ||
| 2000 | 130 | Y712-6 | 0.37 | 61 | 27 | ||
| 3.5S | 960 | 800 | 140 | Y712-6 | 0.25 | 59 | 42 |
| 1500 | 100 | Y712-6 | 0.25 | 59 | 42 | ||
| 2000 | 80 | Y712-6 | 0.25 | 59 | 42 | ||
| 2500 | 50 | Y712-6 | 0.25 | 59 | 42 | ||
| 3.5F | 1450 | 1000 | 320 | Y801-4 | 0.55 | 61 | 45 |
| 2000 | 250 | Y801-4 | 0.55 | 61 | 45 | ||
| 3000 | 190 | Y801-4 | 0.55 | 61 | 45 | ||
| 4000 | 110 | Y801-4 | 0.55 | 61 | 45 | ||
| 4S | 960 | 1000 | 190 | Y801-6 | 0.37 | 60 | 61 |
| 2000 | 150 | Y801-6 | 0.37 | 60 | 61 | ||
| 3000 | 100 | Y801-6 | 0.37 | 60 | 61 | ||
| 4000 | 51 | Y801-6 | 0.37 | 60 | 61 | ||
| 4F | 1450 | 1000 | 420 | Y802-4 | 0.75 | 62 | 67 |
| 2000 | 390 | Y802-4 | 0.75 | 62 | 67 | ||
| 3000 | 280 | Y802-4 | 0.75 | 62 | 67 | ||
| 4000 | 220 | Y802-4 | 0.75 | 62 | 67 | ||
| 4.5S | 960 | 1500 | 360 | Y801-6 | 0.37 | 61 | 70 |
| 3000 | 275 | Y801-6 | 0.37 | 61 | 70 | ||
| 4000 | 150 | Y801-6 | 0.37 | 61 | 70 | ||
| 5000 | 100 | Y801-6 | 0.37 | 61 | 70 | ||
| 4.5F | 1450 | 2000 | 580 | Y90S-4 | 1.1 | 68 | 80 |
| 4000 | 480 | Y90S-4 | 1.1 | 68 | 80 | ||
| 6000 | 350 | Y90S-4 | 1.1 | 68 | 80 | ||
| 7000 | 250 | Y90S-4 | 1.1 | 68 | 80 | ||
| 5S | 960 | 1500 | 360 | Y90S-6 | 0.75 | 63 | 90 |
| 2500 | 290 | Y90S-6 | 0.75 | 63 | 90 | ||
| 4000 | 240 | Y90S-6 | 0.75 | 63 | 90 | ||
| 6000 | 150 | Y90S-6 | 0.75 | 63 | 90 | ||
| 5F | 1450 | 2000 | 710 | Y100L1-4 | 2.2 | 69 | 110 |
| 4000 | 580 | Y100L1-4 | 2.2 | 69 | 110 | ||
| 7000 | 480 | Y100L1-4 | 2.2 | 69 | 110 | ||
| 10000 | 345 | Y100L1-4 | 2.2 | 69 | 110 | ||
| 6S | 960 | 3000 | 480 | Y100L-6 | 1.5 | 65 | 150 |
| 6000 | 360 | Y100L-6 | 1.5 | 65 | 150 | ||
| 8000 | 297 | Y100L-6 | 1.5 | 65 | 150 | ||
| 11000 | 240 | Y100L-6 | 1.5 | 65 | 150 | ||
| 6F | 1450 | 4000 | 1200 | Y132S-4 | 5.5 | 75 | 165 |
| 8000 | 870 | Y132S-4 | 5.5 | 75 | 165 | ||
| 12000 | 690 | Y132S-4 | 5.5 | 75 | 165 | ||
| 18000 | 380 | Y132S-4 | 5.5 | 75 | 165 | ||
| 7S | 960 | 4000 | 600 | Y132S-6 | 3 | 72 | 215 |
| 8000 | 500 | Y132S-6 | 3 | 72 | 215 | ||
| 15000 | 350 | Y132S-6 | 3 | 72 | 215 | ||
| 18000 | 260 | Y132S-6 | 3 | 72 | 215 | ||
| 8E | 720 | 6000 | 700 | Y160M1-8 | 4 | 68 | 372 |
| 10000 | 585 | Y160M1-8 | 4 | 68 | 372 | ||
| 15000 | 510 | Y160M1-8 | 4 | 68 | 372 | ||
| 25000 | 210 | Y160M1-8 | 4 | 68 | 372 | ||
| 8S1 | 960 | 6000 | 780 | Y132M2-6 | 5.5 | 71 | 320 |
| 10000 | 700 | Y132M2-6 | 5.5 | 71 | 320 | ||
| 15000 | 600 | Y132M2-6 | 5.5 | 71 | 320 | ||
| 25000 | 400 | Y132M2-6 | 5.5 | 71 | 320 |
Scroll the table sideways for the remaining columns. The CSV carries every column including efficiency and shaft power.
Design notes
- Short build lengthIdeal for risers and plant rooms where space between dampers is limited.
- High pressure coefficientSmall diameter ratio accelerates flow and raises pressure.
- Low noiseCompared with an axial fan of the same duty, sound power is lower.
Options
- Explosion-proof
- VFD
- Silencer
Applications
- Tight risers
- Retrofit projects
- Hotel and museum ventilation
Same series
CCC certified
Axial, Mixed-Flow & Diagonal Fans
HTF Smoke Extraction Axial Fan
Certified smok…
Airflow2,060–141,086 m³/h
Pressure≤ 1,568 Pa
Open data sheet →
Smoke exhaust duty
Axial, Mixed-Flow & Diagonal Fans
PYHL-14A / HL3-2A Mixed-Flow Fan
Between axial …
Airflow466–145,020 m³/h
Pressure≤ 3,464 Pa
Open data sheet →
Axial, Mixed-Flow & Diagonal Fans
SWF Mixed-Flow Fan
Meridional-acc…
DesignMeridio…
Open data sheet →